Coupling to a Cable from Plane Wave
Model Description
This example considers coupling into simple cable located inside car from external plane wave. Cable paremeters are the following: core radius – 0.0003 m, insulation thickness – 0.0003 m, conductivity values – 5.76e 007 S/m, insulation material permittivity value – 2.3. Frequency range is 1 – 150 MHz
Solution is obtained in Susceptibility Hybrid Analysis Type. Susceptibility Hybrid Analysis Type is intended for immunity analysis of linear and non-linear complex field-cable coupling problems in frequency and time domain. Analysis model is calculated with SPICE3f5 compatible solver.
Susceptibility Hybrid approach in EMC Studio is based on the following scheme:
- Calculation of field distribution along the cable structure with full-wave solver TriD
- The transmission line circuit is supplemented with sources reflecting the incident field
- Analysis model is calculated with SPICE3f5 compatible solver
Simulation Results
Voltage in Probe 1
Voltage in Probe 2